H3C WX Series Getting Started Manual
Hide thumbs Also See for WX Series:

Advertisement

Quick Links

H3C WX Series Access Controllers
Getting Started Guide
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Document Version: 6W100-20101124

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for H3C WX Series

  • Page 1 H3C WX Series Access Controllers Getting Started Guide Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Document Version: 6W100-20101124...
  • Page 2 SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V G, V G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd. All other trademarks that may be mentioned in this manual are the property of their respective owners.
  • Page 3 Preface The H3C WX Series Access Controllers Getting Started Guide describes the installation preparations, login, command line interface (CLI), basic configurations, software maintenance, and troubleshooting of the H3C WX series access controllers. This preface includes: Audience Conventions About the H3C WX Series Documentation Set...
  • Page 4 GUI conventions...
  • Page 5 [Technical Support & Documents > Software Download] – Provides the documentation released with the software version. Technical Support customer_service@h3c.com http://www.h3c.com Documentation Feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments. WX3000 Series Unified Switches Release Operations and...
  • Page 6: Table Of Contents

    Table of Contents 1 Product Overview ······································································································································1-1 WX3000 Series Unified Switches ···········································································································1-1 WX5000 Series Multi-Service Access Controllers ··················································································1-1 WX6000 Series Carrier-Class Multi-Service Access Controllers····························································1-1 2 Installation Preparations···························································································································2-1 3 Installing an AC··········································································································································3-1 4 Logging In to an AC···································································································································4-1 Powering on the AC and Connecting It to a Network ·············································································4-1 Logging In to an AC ································································································································4-1 5 Configuring Basic Functions ···················································································································5-1 Specifying an IP Address for an AC········································································································5-3...
  • Page 7: Product Overview

    Product Overview Developed by Hangzhou H3C Technologies Co., Ltd (hereinafter referred to as H3C), H3C WX series access controllers (ACs) (hereinafter referred to as the WX series) include ACs, access controller modules, and unified switches switching engines. The WX series include the WX3000 series, WX5000 series, and WX6000 series.
  • Page 8: Installation Preparations

    Installation Preparations Preparations for installing WX series access controllers include precautions, preparation of installation tools, environment examination, and...
  • Page 9: Installing An

    Installing an AC When...
  • Page 10: Logging In To An

    Before logging in to an AC, power on the AC and connect it to a network. For more information, see Powering on the AC and Connecting It to a Network. You can use any of the following methods to log in to a WX series access controller: Logging in through the console port Logging in through telnet...
  • Page 11: Configuring Basic Functions

    Configuring Basic Functions The WX series access controller has the default configuration as follows: The default output depends on your AC model. version 5.20, Release 2106P01 sysname H3C undo info-center logfile enable domain default enable system telnet server enable port-security enable...
  • Page 12 Table 5-1 Description of the default configuration Field Description version 5.20, Release 2106P01 The AC software version currently in use The default sysname is H3C. sysname H3C undo info-center logfile enable Disable the logfile function. domain default enable system The default enabled domain is system.
  • Page 13: Specifying An Ip Address For An

    Field Description wlan rrm dot11a mandatory-rate 6 12 24 dot11a supported-rate 9 18 36 48 54 The default 802.11a/b/g settings are as shown on the left column. dot11b mandatory-rate 1 2 The default rates depend on your AC model. dot11b supported-rate 5.5 11 dot11g mandatory-rate 1 2 5.5 11 dot11g supported-rate 6 9 12 18 24 36 48 54 interface NULL0...
  • Page 14: Configuring Wlan Service

    By default, the country code value is CN. For more information about country code and country, see WLAN Service in the WLAN Command Reference in the H3C WX Series Access Controllers Command References. Specifies a country code wlan country-code code...
  • Page 15 To do… Use the command… Remarks Exit interface view quit Required wlan service-template Required Create a WLAN service service-template-number template By default, no service template is created. { clear | crypto } Required Specify the service set ssid ssid-name identifier (SSID) By default, no SSID is set.
  • Page 16: Configuration File Encryption

    Task Remarks Configuration File Encryption Optional Modes in Saving the Configuration Required Configuration File Encryption Support for this feature depends on the AC model. This feature enables you to encrypt a configuration file before saving it (using the save command). If you want to read the encrypted configuration file, you must decrypt it with a legal key.
  • Page 17 Safe mode. Safe mode is implemented by using the save command with the safely keyword. The mode saves the file more slowly than the fast saving mode, but can retain the configuration file on the device even if the device reboots or the power fails during the process. The fast saving mode is suitable for environments where power supply is stable.
  • Page 18: Software Maintenance

    Software Maintenance If an installation guide is supplied with the AC, see Software Maintenance in the installation guide. If a card manual is supplied with the AC, see H3C Access Controller Modules Software Upgrade Guide.
  • Page 19: Troubleshooting

    Troubleshooting This chapter describes how to troubleshoot H3C WX series access controllers problems. If you cannot solve a system problem, contact the H3C technical support staff. Technical support: customer_service@h3c.com http://www.h3c.com The AC Cannot Connect to the Network Symptom After you connect a network cable to the AC, the AC cannot connect to the network.
  • Page 20: 10-Ge Interface Card Problem Of The Wx3024

    Connect the two ends of the optical fiber to the TX and RX ends of the same optical transceiver to check connectivity of the optical interfaces. If the optical interfaces still cannot connect to the network, connect the optical fiber in the same way to the optical interfaces that work normally. If the optical interfaces still cannot connect to the network, the optical transceiver is faulty.
  • Page 21: No Information Of The Serial Port Is Output

    <Sysname>display environment System Temperature information (degree centigrade): ---------------------------------------------------- SlotNo Temperature Lower limit Upper limit <Sysname>display environment System CPU Temperature information (degree centigrade): ---------------------------------------------------- SlotNo Temperature Lower limit Upper limit Figure 7-1 display environment command output description Field Description Temperature information of cards (in degree System Temperature information (degree centigrade) centigrade) SlotNo...
  • Page 22 Analysis A switch supporting PoE has certain specifications in PoE power supply. When the total supplied power exceeds the maximum power supply capacity of the switch, the switch automatically disconnects some ports with lower priority. Therefore, APs attached to these ports will restart. Check the log information on the switch: #Apr 6 11:26:44:368 2000 YXY-WLAN-04 DRV_DEM/5/POE WARNING:- 1 -Power budget exceeded...
  • Page 23: The Main Control Board On The Wx6103 Access Controller Cannot Be Started

    If the problem still exists, contact the service engineer. The Main Control Board on the WX6103 Access Controller Cannot Be Started Symptom The WX6103 access controller main control board cannot be started, and you cannot enter the user prompt. Solution Check that: The main control board can be powered on, and RUN LED of the corresponding slots blinks, indicating the main control board is working normally.
  • Page 24: Index

    Index 10-GE Interface Card Problem of the WX3000 Series Unified Switches WX3024 WX5000 Series Multi-Service Access Controllers WX6000 Series Carrier-Class Multi-Service Configuration File Encryption Access Controllers Configuring WLAN Service Logging In to an AC Modes in Saving the Configuration No Information of the Serial Port Is Output Over-Temperature Alarm Powering on the AC and Connecting It to a Network...

This manual is also suitable for:

Wx3000 seriesWx5000 series

Table of Contents