6.5.19 Power Restoration Procedure
Is the EZJ133board
CN1 connector
disconnected or in
poor contact?
Is the EZJ128 board
CN1 connector
disconnected or in
poor contact?
Replace the EZJ133 board.*1
Does the fault recur?
Replace the EZJ128 board.*2
(*1): When you replace EZJ133 board, refer to [Replacement procedures of EZJ133 board] in "3.3.1 EZJ133 board (MPU
board)".
(*2): When you replace EZJ 128 board, refer to [Replacement procedures of EZJ128 board] in "3.2.1 EZJ128 board
(controller board)".
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to [Connector numbers and Identifying method
of harnesses] in "3.3.20 Electrical Connection Diagram".
Power Restoration
Procedure
No
No
No
Resume the
operation.
Yes
Yes
Remove the connector once and
reconnect it.