Hitachi UX Twin Nozzle Service Manual page 342

Hide thumbs Also See for UX Twin Nozzle:
Table of Contents

Advertisement

6.5.17 Power does not turn OFF after pressing Stop button
Does the trouble fixed when the connetors
below are disconnected once and reconnected?
-CN20, CN23, CN2, CN34 and CN28 of EZJ133
-CN4 of EZJ113
-CN4 of EZJ139
-CN2 of EZJ114
Does the trouble fixed after
replacing the EZJ114 board? *1
Does the trouble fixed after
replacing the EZJ113 board? *2
Does the trouble fixed after
replacing the EZJ134 board? *3
Does the trouble fixed after
replacing the multiple DC
power supply1 ? *4
Replace the EZJ133 board. *5
Power does not
turn OFF
No
Yes
No
No
Yes
Yes
6-100
(*1): When you replace EZJ114 board,
(*2): When you replace EZJ113 board, refer
Yes
(*3): When you replace EZJ134 board, refer
(*4): When you replace Multiple power
Yes
(*5): When you replace EZJ133 board,
[Caution]
Be sure to check that there is no wrong
connection of harnesses by referring to
[Connector
method of harnesses] in "3.3.20 Electrical
Resume the
operation
Connection Diagram".
refer to [Notes in case of the board
replacement]
in
"3.3.11
board (LED / SW board)".
to
[Replacement
procedures
EZJ113 board] in "3.3.19 EZJ113
board (Power relay board 1)".
to
[Replacement
procedures
EZJ134 board] in "3.3.6 EZJ134
board (Nozzle2 drive board)".
supply1,
refer
to
[Replacement
procedures of multiple power supply]
in 3.3.15 Multiple Power Supply 1
and 2.
refer to [Replacement procedures of
EZJ133 board] in "3.3.1 EZJ133
board (MPU board)".
numbers
and
Identifying
EZJ114
of
of

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents