Hitachi UX Twin Nozzle Service Manual page 291

Hide thumbs Also See for UX Twin Nozzle:
Table of Contents

Advertisement

6.3.2 Barcode Short On Numbers
Barcode Short On Numbers
Input the fixed number of character for EAN-13,
EAN-8, UPC-A, UPC-E and GS-1 data bar
Resume the operation.
When country code is input
on edit message screen
EAN-13
EAN-8
UPC-A
UPC-E
GS-1
data bar
Refer to the Instruction Manual, "4.13.3 Set various printing".
6.3.3 Shutdown Fault
Shutdown Fault
Disconnect the EZJ113 board CN4 connector and
EZJ133 CN20 connector and reconnect them.
Disconnect the EZJ139 board CN4 connector and
EZJ133 board CN34 connector and reconnect them.
Is the fault issued
again?
Replace the EZJ113 board.*1.
Replace the EZJ139 board.*2
Is the fault issued
again?
Replace the EZJ133.*3
Fixed character number
12
7
Limited:13
Omnidirectional:13
No
Yes
No
No
No
Yes
6-49
When country code is input
on print format screen
10
5
11
8
(*1): When you replace EZJ113 board, refer to
[Replacement procedures of EZJ113 board] in
"3.3.9 EZJ113 board (Power relay board 1)".
(*2): When you replace EZJ139 board, refer to
[Replacement procedures of EZJ139 board] in
"3.3.10 EZJ139 board (Power relay board 2)".
(*3): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board] in
"3.3.1 EZJ133 board (MPU board)".
[Caution]
Be sure to check that there is no wrong connection
of harnesses by referring to [Connector numbers and
Identifying
Electrical Connection Diagram".
Resume the
operation.
method
of
harnesses]
in
"3.3.20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents