13 Remove the fixing screws (2 positions) and take out the inner cover (B)
14 Clean the portion stained with ink and then install the main ink tank in reverse order of the
procedures above.
15 Route the solenoid cable to the hook of the inner cover (B).
(Refer to the figure in step 10 for how to route the Solenoid Cable.)
16 Install the new Makeup Reservoir in reverse order of the procedures above.
[Caution] When installing the Makeup Reservoir, confirm that the Solenoid Cable is
routed to the hook of the inner cover (B).
When installing the Makeup Reservoir, out the hook of the Makeup reservoir
into the hole of the Reservoir base first.
Makeup reservoir
Hook
17 Perform "Ink refill" and make sure that there is no ink leak.
4.2.3 Removal method of the Main ink tank lid
Fixing screws
Reservoir base
Pay attention NOT to pinch the Solenoid Cable.
[Cautions when URGENT OVERHAUL of the Main tank is
required]
• Main ink tank can be overhauled by unfastening the screws
on top.
• Prepare a new Main tank packing before starting the
overhaul.
* In some cases, the Main tank packing mounted between
The Main ink tank and the lid may be deformed and may
not be put back in.
4-11
Main ink tank
Inner cover (B)
Makeup reservoir
Fixing screws(8pcs)
Reservoir base
Hook