6.4.3 Viscosity Readings Out of Range
Viscosity Reading
Out of Range
Perform the viscometer
operation test on the
Circulation system control
screen.
Is it normally
measured?
Yes
Resume the
operation.
(*1) (*2): When you disassemble and clean or replace the Viscometer, refer to "4. 12
Troubleshooting when Fault Occurs in Viscometer".
No
Yes
Disconnect and reconnect the
following connectors.
▪ EZJ133: CN13, CN22, CN32
▪ EZJ138: CN1 to 6
▪ Proximity sensor, viscosity
Yes
Yes
Perform the viscometer
calibration
6-66
Replace the ink.
Is it normally measured?
No
Is it normally measured?
No
Disassemble and clean the
viscometer. *1
Is it normally measured?
No
Replace the viscometer*2