6.2.18b (N2)Ink Heating Unit Over Current
(N2)Ink Heating Unit
Over Current
Is the PTC resistance
measured (between the
EZJ133 board TP3 and TP24)
lower than 23 ?
Yes
Replace the heating unit.
▪ Clear the fault.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Does the fault recur?
Yes
Replace the EZJ133 board*2.
▪ Clear the fault.
▪ From the maintenance screen, place
the heating unit in the operating mode. *)
▪ Restart the IJ printer.
Does the fault recur?
Yes
Replace the print head*3.
- On detecting this fault, the IJ printer automatically sets the "Ink temperature
correction" to (disable).
"System environment setup: Ink temperature correction (enable)  (disable)"
After getting rid of the fault, reset the Ink temperature correction to (enable).
"System environment setup: Ink temperature correction (disable)  (enable)"
- In the condition of the "Ink temperature correction (disable), " the "Ink Temperature
Correction Notice" message appears each time the power is turned on.
(See "1.6 Heating of Ink" in the Instruction manual".)
No
*1
No
No
Resume the
operation.
Caution
!
6-32
(*1): When you replace Heating unit, refer to "5.6 Heating
unit replacement".
(*2): When you replace EZJ133 board, refer to
procedures of EZJ133 board]
(MPU board)".
(*3): When you replace the printhead, refer to
Head Replacement Procedure".
[Caution]
Be sure to check that there is no wrong connection of
harnesses by referring to
method of harnesses]
Diagram".
*) Refer to the
following caution.
*) Refer to the
following caution.
[Replacement
"3.3.1 EZJ133 board
in
"4.13 Print
[Connector numbers and Identifying
in
"3.3.20 Electrical Connection

Hide quick links: