6.2.26b (N2)Charge Voltage Too Low
(N2)Charge Voltage Too Low
Clear the fault.
Place the printer in The "Ready" state.
Does the fault recur?
Replace the EZJ134 board. *1
Does the fault recur?
Replace the high-voltage power supply2. *2
Does the fault recur?
Replace the EZJ133 board. *3
(*1): When you replace EZJ134 board, refer to [Replacement procedures of EZJ134 board] in "3.3.6 EZJ134 board
(Nozzle2 drive board)".
(*2): When you replace High voltage power supply 2, refer to [Replacement procedures of high voltage power
supply] in "3.3.16 High Voltage Power Supply 1 and 2".
(*3): When you replace EZJ133 board, refer to
(MPU board)".
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to
Identifying method of harnesses]
No
Yes
No
Yes
No
Yes
[Replacement procedures of EZJ133 board]
"3.3.20 Electrical Connection Diagram".
in
6-41
Resume the
operation.
in
"3.3.1 EZJ133 board
[Connector numbers and