6.2.23b (N2)Ink Heating Unit Temperature Low
(N2)Ink Heating Unit Temperature
Low
Disconnect the EZJ133
board CN38 connector and
reconnect it.
Is the fault issued
again?
Replace the heating unit. *1
Is the fault issued
again?
Replace the EZJ133 board. *2
(*1): When you replace Heating unit, refer to "5.6 Heating unit replacement".
(*2): When you replace EZJ133 board, refer to
(MPU board)".
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to
Identifying method of harnesses]
No
Yes
No
Yes
[Replacement procedures of EZJ133 board]
"3.3.20 Electrical Connection Diagram".