6.2.11b Multi DC Power Supply2 Fan Fault
Multi DC Power
Supply2 Fan Fault
Is the multiple power supply2
fan running?
Replace the EZJ133 board. *1
Is the problem fixed?
Replace the multiple power supply2
No
Yes
Yes
END
No
(*1): When you replace EZJ133 board, refer to
EZJ133 board]
[Caution]
Be sure to check that there is no wrong connection of harnesses by
[Connector numbers and Identifying method of harnesses]
referring to
"3.3.20 Electrical Connection Diagram".
6-23
Is the EZJ133 CN28 connector
or multiple power supply CN4
connector disconnected?
No
Connect the connector.
[Replacement procedures of
in
"3.3.1 EZJ133 board (MPU board)".
Yes
in

Hide quick links: