5.9 TRANSDUCER INPUTS AND OUTPUTS
RTD INPUT H1 TYPE: This setting specifies the RTD type. Four different RTD types are available: 100 Ω Nickel, 10 Ω
Copper, 100 Ω Platinum, and 120 Ω Nickel. Refer the table below for reference temperature values for each type.
Table 5–36: RTD TEMPERATURE VS. RESISTANCE
TEMPERATURE
°C
°F
–50
–58
–40
–40
–30
–22
–20
–4
–10
14
0
32
10
50
20
68
30
86
40
104
50
122
60
140
70
158
80
176
90
194
5
100
212
110
230
120
248
130
266
140
284
150
302
160
320
170
338
180
356
190
374
200
392
210
410
220
428
230
446
240
464
250
482
RTD INPUT H1 APPLICATION: This setting allows each individual RTD to be assigned to a group application. This is
useful for applications that require group measurement for voting. A value of "None" specifies that the RTD will operate
individually and not part of any RTD group. All RTDs programmed to "Stator" are used for RTD biasing of the G60 ther-
mal model. Common groups are provided for rotating machines applications such as ambient, bearing, group 1, or
group 2. If the
RTD INPUT H1 TRIP VOTING
same group also pick up, where N is the number of enabled RTDs from the group.
RTD INPUT H1 ALARM TEMPERATURE: This setting specifies the temperature pickup level for the alarm stage.
RTD INPUT H1 ALARM PKP DELAY: This setting specifies time delay for the alarm stage until the output can be
asserted.
RTD INPUT H1 TRIP TEMPERATURE: This setting specifies the temperature pickup level for the trip stage.
RTD INPUT H1 TRIP PKP DELAY: This setting specifies time delay for the trip stage until the output can be asserted.
5-312
RESISTANCE (IN OHMS)
100 OHM PT
120 OHM NI
100 OHM NI
(DIN 43760)
80.31
86.17
71.81
84.27
92.76
77.30
88.22
99.41
82.84
92.16
106.15
88.45
96.09
113.00
94.17
100.00
120.00
100.00
103.90
127.17
105.97
107.79
134.52
112.10
111.67
142.06
118.38
115.54
149.79
124.82
119.39
157.74
131.45
123.24
165.90
138.25
127.07
174.25
145.20
130.89
182.84
152.37
134.70
191.64
159.70
138.50
200.64
167.20
142.29
209.85
174.87
146.06
219.29
182.75
149.82
228.96
190.80
153.58
238.85
199.04
157.32
248.95
207.45
161.04
259.30
216.08
164.76
269.91
224.92
168.47
280.77
233.97
172.46
291.96
243.30
175.84
303.46
252.88
179.51
315.31
262.76
183.17
327.54
272.94
186.82
340.14
283.45
190.45
353.14
294.28
194.08
366.53
305.44
setting value is "Group", then it is allowed to issue a trip if N – 1 RTDs from the
G60 Generator Protection System
10 OHM CU
7.10
7.49
7.88
8.26
8.65
9.04
9.42
9.81
10.19
10.58
10.97
11.35
11.74
12.12
12.51
12.90
13.28
13.67
14.06
14.44
14.83
15.22
15.61
16.00
16.39
16.78
17.17
17.56
17.95
18.34
18.73
5 SETTINGS
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents