B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 60 of 68)
ADDR
REGISTER NAME
C8E4
...Repeated for Direct Input 22
C8E8
...Repeated for Direct Input 23
C8EC
...Repeated for Direct Input 24
C8F0
...Repeated for Direct Input 25
C8F4
...Repeated for Direct Input 26
B
C8F8
...Repeated for Direct Input 27
C8FC
...Repeated for Direct Input 28
C900
...Repeated for Direct Input 29
C904
...Repeated for Direct Input 30
C908
...Repeated for Direct Input 31
C90C
...Repeated for Direct Input 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0
Direct Input/Output Channel 1 CRC Alarm Function
CAD1
Direct Input/Output Channel 1 CRC Alarm Message Count
CAD2
Direct Input/Output Channel 1 CRC Alarm Threshold
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
CAD4
Reserved (4 items)
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
CAD9
Direct Input/Output Channel 2 CRC Alarm Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct Input/Output Ch 1 Unreturned Messages Alarm
Function
CAE1
Direct Input/Output Ch 1 Unreturned Messages Alarm Msg
Count
CAE2
Direct Input/Output Ch 1 Unreturned Messages Alarm
Threshold
CAE3
Direct Input/Output Ch 1 Unreturned Messages Alarm
Events
CAE4
Reserved (4 items)
CAE8
Direct Input/Output Ch 2 Unreturned Messages Alarm
Function
CAE9
Direct Input/Output Ch 2 Unreturned Messages Alarm Msg
Count
CAEA
Direct Input/Output Ch 2 Unreturned Messages Alarm
Threshold
CAEB
Direct Input/Output Channel 2 Unreturned Messages Alarm
Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID (GOID)
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
Remote Device 1 in PMU Scheme
CB24
Reserved
CB25
...Repeated for Device 2
CB4A
...Repeated for Device 3
CB6F
...Repeated for Device 4
CB94
...Repeated for Device 5
CBB9
...Repeated for Device 6
CBDE
...Repeated for Device 7
CC03
...Repeated for Device 8
CC28
...Repeated for Device 9
CC4D
...Repeated for Device 10
CC72
...Repeated for Device 11
B-68
RANGE
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
---
0 to 16383
0 to 16
0 to 1
0 to 3
G60 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F209
"Remote Device
---
1
F001
---
1
F184
---
1
F126
---
1
F626
DEFAULT
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
1"
0
0 (Fixed)
0 (No)