APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 59 of 68)
ADDR
REGISTER NAME
C64B
...Repeated for Direct Output 26
C64E
...Repeated for Direct Output 27
C651
...Repeated for Direct Output 28
C654
...Repeated for Direct Output 29
C657
...Repeated for Direct Output 30
C65A
...Repeated for Direct Output 31
C65D
...Repeated for Direct Output 32
Reset (Read/Write Setting)
C750
FlexLogic operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input x State (96 items)
C800
Force Contact Output x State (64 items)
Direct Inputs/Outputs (Read/Write Setting)
C880
Direct Device ID
C881
Direct I/O Channel 1 Ring Configuration Function
C882
Platform Direct I/O Data Rate
C883
Direct I/O Channel 2 Ring Configuration Function
C884
Platform Direct I/O Crossover Function
Direct Input/Output Commands (Read/Write Command)
C888
Direct Input/Output Clear Counters Command
Direct Inputs (Read/Write Setting) (32 modules)
C890
Direct Input 1 Device Number
C891
Direct Input 1 Number
C892
Direct Input 1 Default State
C893
Direct Input 1 Events
C894
...Repeated for Direct Input 2
C898
...Repeated for Direct Input 3
C89C
...Repeated for Direct Input 4
C8A0
...Repeated for Direct Input 5
C8A4
...Repeated for Direct Input 6
C8A8
...Repeated for Direct Input 7
C8AC
...Repeated for Direct Input 8
C8B0
...Repeated for Direct Input 9
C8B4
...Repeated for Direct Input 10
C8B8
...Repeated for Direct Input 11
C8BC
...Repeated for Direct Input 12
C8C0
...Repeated for Direct Input 13
C8C4
...Repeated for Direct Input 14
C8C8
...Repeated for Direct Input 15
C8CC
...Repeated for Direct Input 16
C8D0
...Repeated for Direct Input 17
C8D4
...Repeated for Direct Input 18
C8D8
...Repeated for Direct Input 19
C8DC
...Repeated for Direct Input 20
C8E0
...Repeated for Direct Input 21
GE Multilin
RANGE
0 to 4294967295
0 to 1
0 to 1
0 to 2
0 to 3
1 to 16
0 to 1
64 to 128
0 to 1
0 to 1
0 to 1
0 to 16
0 to 96
0 to 3
0 to 1
G60 Generator Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
---
1
F144
---
1
F131
---
1
F001
---
1
F126
kbps
64
F001
---
1
F126
---
1
F102
---
1
F126
---
1
F001
---
1
F001
---
1
F086
---
1
F102
DEFAULT
B
0
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
1
0 (No)
64
0 (No)
0 (Disabled)
0 (No)
0
0
0 (Off)
0 (Disabled)
B-67