B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 4 of 68)
ADDR
REGISTER NAME
15D2
Direct Inputs/Outputs CRC Fail Count 1
15D3
Direct Inputs/Outputs CRC Fail Count 2
Field Unit Input/Output States (Read Only)
15E0
Field Unit Contact Input States (3 items)
15E3
Field Unit Contact Input Output Operand States (8 items)
B
15EB
Field Contact Output Physical States (8 items)
15F3
Field Contact Output Current States (8 items)
15FB
Field Contact Output Physical States (8 items)
1603
Field Shared Input States
1604
Field Shared Input Channel States
1605
Field Shared Input Test States
1606
Field Shared Output Operand States
1607
Field Latching Output Open Operand States
1608
Field Latching Output Close Operand States
1609
Field Latching Output Open Driver States
160A
Field Latching Output Close Driver States
160B
Field Latching Output Physical States
160C
Field Unit Online/Offline States
160D
Field RTD Input Trouble States
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
1612
Ethernet Tertiary Fibre Channel Status
Data Logger Actual Values (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
Stator Differential Actual Values (Read Only)
1660
Generator Differential Iad
1662
Generator Restraint Iar
1664
Generator Differential Ibd
1666
Generator Restraint Ibr
1668
Generator Differential Icd
166A
Generator Restraint Icr
166C
Stator Differential CT Primary
Stator Ground Actual Values (Read Only)
1670
Stator Ground Vn 3rd
1672
Stator Ground Vn V0 3rd
1674
Stator Ground V0 3rd
Subharmonic Stator Ground Actual Values (Read Only)
1678
Subharmonic Injection Voltage
167A
Subharmonic Injection Current
167C
Stator Ground Resistance
167E
Reserved
167F
Subharmonic Injection Current Angle
Sensitive Directional Power Actual Values (Read Only) (2 modules)
1680
Sensitive Directional Power 1 Power
1682
Sensitive Directional Power 2 Power
Restricted Ground Fault Currents (Read Only) (6 modules)
16A0
Differential Ground Current Magnitude
16A2
Restricted Ground Current Magnitude
16A4
...Repeated for Restricted Ground Fault 2
B-12
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 50000
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 500
0 to 0.1
-360 to 360
-2147483647 to 2147483647
-2147483647 to 2147483647
0 to 999999.999
0 to 999999.999
G60 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
---
1
F060
V
0.001
F060
V
0.001
F060
V
0.001
F060
V
0.001
F060
A
0.001
F060
kOhm
0.001
F003
---
0.1
F208
---
0.1
F002
W
1
F060
W
1
F060
A
0.001
F060
A
0.001
F060
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
500000
(none)
0
0
0
0
0