GE G60 Instruction Manual page 650

Ur series generator protection system
Hide thumbs Also See for G60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 48 of 68)
ADDR
REGISTER NAME
A964
Restricted Ground Fault 1 Delay
A965
Restricted Ground Fault 1 Reset Delay
A966
Restricted Ground Fault 1 Block
A968
Restricted Ground Fault 1 Target
A969
Restricted Ground Fault 1 Events
B
A96A
...Repeated for Restricted Ground Fault 2
A974
...Repeated for Restricted Ground Fault 3
A97E
...Repeated for Restricted Ground Fault 4
A988
...Repeated for Restricted Ground Fault 5
A992
...Repeated for Restricted Ground Fault 6
IEC 61850 Received Analog Settings (Read/Write Setting) (32 modules)
AA00
IEC 61850 GOOSE Analog 1 Default Value
AA02
IEC 61850 GOOSE Analog Input 1 Mode
AA03
IEC 61850 GOOSE Analog Input 1 Units
AA05
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
AA07
...Repeated for IEC 61850 GOOSE Analog Input 2
AA0E
...Repeated for IEC 61850 GOOSE Analog Input 3
AA15
...Repeated for IEC 61850 GOOSE Analog Input 4
AA1C
...Repeated for IEC 61850 GOOSE Analog Input 5
AA23
...Repeated for IEC 61850 GOOSE Analog Input 6
AA2A
...Repeated for IEC 61850 GOOSE Analog Input 7
AA31
...Repeated for IEC 61850 GOOSE Analog Input 8
AA38
...Repeated for IEC 61850 GOOSE Analog Input 9
AA3F
...Repeated for IEC 61850 GOOSE Analog Input 10
AA46
...Repeated for IEC 61850 GOOSE Analog Input 11
AA4D
...Repeated for IEC 61850 GOOSE Analog Input 12
AA54
...Repeated for IEC 61850 GOOSE Analog Input 13
AA5B
...Repeated for IEC 61850 GOOSE Analog Input 14
AA62
...Repeated for IEC 61850 GOOSE Analog Input 15
AA69
...Repeated for IEC 61850 GOOSE Analog Input 16
AA70
...Repeated for IEC 61850 GOOSE Analog Input 17
AA77
...Repeated for IEC 61850 GOOSE Analog Input 18
AA7E
...Repeated for IEC 61850 GOOSE Analog Input 19
AA85
...Repeated for IEC 61850 GOOSE Analog Input 20
AA8C
...Repeated for IEC 61850 GOOSE Analog Input 21
AA93
...Repeated for IEC 61850 GOOSE Analog Input 22
AA9A
...Repeated for IEC 61850 GOOSE Analog Input 23
AAA1
...Repeated for IEC 61850 GOOSE Analog Input 24
AAA8
...Repeated for IEC 61850 GOOSE Analog Input 25
AAAF
...Repeated for IEC 61850 GOOSE Analog Input 26
AAB6
...Repeated for IEC 61850 GOOSE Analog Input 27
AABD
...Repeated for IEC 61850 GOOSE Analog Input 28
AAC4
...Repeated for IEC 61850 GOOSE Analog Input 29
AACB
...Repeated for IEC 61850 GOOSE Analog Input 30
AAD2
...Repeated for IEC 61850 GOOSE Analog Input 31
AAD9
...Repeated for IEC 61850 GOOSE Analog Input 32
IEC 61850 XCBR Configuration (Read/Write Settings and Commands) (6 modules)
AB00
Operand for IEC 61850 XCBR1.ST.Loc status
AB02
Command to Clear XCBR1 OpCnt (Operation Counter)
AB03
Operand for IEC 61850 XCBR Check Sync Release
AB05
Operand for IEC 61850 XCBR Open Interlock
AB07
Operand for IEC 61850 XCBR Close Interlock
AB09
Operand for IEC 61850 XCBR Pos ct1Model
AB0A
Operand for IEC 61850 XCBR Pos sboTimeout
B-56
RANGE
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
–1000000 to 1000000
0 to 1
---
0 to 999999999.999
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4
2 to 60
G60 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
0.001
F060
---
1
F491
0 (Default Value)
---
---
F207
---
0.001
F060
---
1
F300
---
1
F126
---
1
F300
---
1
F300
---
1
F300
---
1
F001
s
1
F001
DEFAULT
0
0
0
0 (Self-reset)
0 (Disabled)
1000
(none)
1
0
0 (No)
0
0
0
2
30
GE Multilin