GE G60 Instruction Manual page 582

Ur series generator protection system
Hide thumbs Also See for G60:
Table of Contents

Advertisement

A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 16 of 27)
A
ADDRESS
FLEXANALOG NAME
10312
SRC 1 Ic Harm[5]
10313
SRC 1 Ic Harm[6]
10314
SRC 1 Ic Harm[7]
10315
SRC 1 Ic Harm[8]
10316
SRC 1 Ic Harm[9]
10317
SRC 1 Ic Harm[10]
10318
SRC 1 Ic Harm[11]
10319
SRC 1 Ic Harm[12]
10320
SRC 1 Ic Harm[13]
10321
SRC 1 Ic Harm[14]
10322
SRC 1 Ic Harm[15]
10323
SRC 1 Ic Harm[16]
10324
SRC 1 Ic Harm[17]
10325
SRC 1 Ic Harm[18]
10326
SRC 1 Ic Harm[19]
10327
SRC 1 Ic Harm[20]
10328
SRC 1 Ic Harm[21]
10329
SRC 1 Ic Harm[22]
10330
SRC 1 Ic Harm[23]
10339
SRC 2 Ia THD
10340
SRC 2 Ia Harm[0]
10341
SRC 2 Ia Harm[1]
10342
SRC 2 Ia Harm[2]
10343
SRC 2 Ia Harm[3]
10344
SRC 2 Ia Harm[4]
10345
SRC 2 Ia Harm[5]
10346
SRC 2 Ia Harm[6]
10347
SRC 2 Ia Harm[7]
10348
SRC 2 Ia Harm[8]
10349
SRC 2 Ia Harm[9]
10350
SRC 2 Ia Harm[10]
10351
SRC 2 Ia Harm[11]
10352
SRC 2 Ia Harm[12]
10353
SRC 2 Ia Harm[13]
10354
SRC 2 Ia Harm[14]
10355
SRC 2 Ia Harm[15]
10356
SRC 2 Ia Harm[16]
10357
SRC 2 Ia Harm[17]
10358
SRC 2 Ia Harm[18]
10359
SRC 2 Ia Harm[19]
10360
SRC 2 Ia Harm[20]
10361
SRC 2 Ia Harm[21]
10362
SRC 2 Ia Harm[22]
10363
SRC 2 Ia Harm[23]
10372
SRC 2 Ib THD
10373
SRC 2 Ib Harm[0]
10374
SRC 2 Ib Harm[1]
A-16
UNITS
DESCRIPTION
%
Source 1 phase C current seventh harmonic
%
Source 1 phase C current eighth harmonic
%
Source 1 phase C current ninth harmonic
%
Source 1 phase C current tenth harmonic
%
Source 1 phase C current eleventh harmonic
%
Source 1 phase C current twelfth harmonic
%
Source 1 phase C current thirteenth harmonic
%
Source 1 phase C current fourteenth harmonic
%
Source 1 phase C current fifteenth harmonic
%
Source 1 phase C current sixteenth harmonic
%
Source 1 phase C current seventeenth harmonic
%
Source 1 phase C current eighteenth harmonic
%
Source 1 phase C current nineteenth harmonic
%
Source 1 phase C current twentieth harmonic
%
Source 1 phase C current twenty-first harmonic
%
Source 1 phase C current twenty-second harmonic
%
Source 1 phase C current twenty-third harmonic
%
Source 1 phase C current twenty-fourth harmonic
%
Source 1 phase C current twenty-fifth harmonic
%
Source 2 phase A current total harmonic distortion
%
Source 2 phase A current second harmonic
%
Source 2 phase A current third harmonic
%
Source 2 phase A current fourth harmonic
%
Source 2 phase A current fifth harmonic
%
Source 2 phase A current sixth harmonic
%
Source 2 phase A current seventh harmonic
%
Source 2 phase A current eighth harmonic
%
Source 2 phase A current ninth harmonic
%
Source 2 phase A current tenth harmonic
%
Source 2 phase A current eleventh harmonic
%
Source 2 phase A current twelfth harmonic
%
Source 2 phase A current thirteenth harmonic
%
Source 2 phase A current fourteenth harmonic
%
Source 2 phase A current fifteenth harmonic
%
Source 2 phase A current sixteenth harmonic
%
Source 2 phase A current seventeenth harmonic
%
Source 2 phase A current eighteenth harmonic
%
Source 2 phase A current nineteenth harmonic
%
Source 2 phase A current twentieth harmonic
%
Source 2 phase A current twenty-first harmonic
%
Source 2 phase A current twenty-second harmonic
%
Source 2 phase A current twenty-third harmonic
%
Source 2 phase A current twenty-fourth harmonic
%
Source 2 phase A current twenty-fifth harmonic
%
Source 2 phase B current total harmonic distortion
%
Source 2 phase B current second harmonic
%
Source 2 phase B current third harmonic
G60 Generator Protection System
APPENDIX A
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents