GE G60 Instruction Manual page 580

Ur series generator protection system
Hide thumbs Also See for G60:
Table of Contents

Advertisement

A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 14 of 27)
A
ADDRESS
FLEXANALOG NAME
9223
Synchchk 2 Delta Phs
9224
Synchchk 3 Delta V
9226
Synchchk 3 Delta F
9227
Synchchk 3 Delta Phs
9228
Synchchk 4 Delta V
9230
Synchchk 4 Delta F
9231
Synchchk 4 Delta Phs
9536
PMU 1 Va Mag
9538
PMU 1 Va Angle
9539
PMU 1 Vb Mag
9541
PMU 1 Vb Angle
9542
PMU 1 Vc Mag
9544
PMU 1 Vc Angle
9545
PMU 1 Vx Mag
9547
PMU 1 Vx Angle
9548
PMU 1 V1 Mag
9550
PMU 1 V1 Angle
9551
PMU 1 V2 Mag
9553
PMU 1 V2 Angle
9554
PMU 1 V0 Mag
9556
PMU 1 V0 Angle
9557
PMU 1 Ia Mag
9559
PMU 1 Ia Angle
9560
PMU 1 Ib Mag
9562
PMU 1 Ib Angle
9563
PMU 1 Ic Mag
9565
PMU 1 Ic Angle
9566
PMU 1 Ig Mag
9568
PMU 1 Ig Angle
9569
PMU 1 I1 Mag
9571
PMU 1 I1 Angle
9572
PMU 1 I2 Mag
9574
PMU 1 I2 Angle
9575
PMU 1 I0 Mag
9577
PMU 1 I0 Angle
9578
PMU 1 Freq
9580
PMU 1 df dt
9581
PMU 1 Conf Ch
10240
SRC 1 Ia THD
10241
SRC 1 Ia Harm[0]
10242
SRC 1 Ia Harm[1]
10243
SRC 1 Ia Harm[2]
10244
SRC 1 Ia Harm[3]
10245
SRC 1 Ia Harm[4]
10246
SRC 1 Ia Harm[5]
10247
SRC 1 Ia Harm[6]
10248
SRC 1 Ia Harm[7]
A-14
UNITS
DESCRIPTION
Degrees
Synchrocheck 2 delta phase
Volts
Synchrocheck 3 delta voltage
Hz
Synchrocheck 3 delta frequency
Degrees
Synchrocheck 3 delta phase
Volts
Synchrocheck 4 delta voltage
Hz
Synchrocheck 4 delta frequency
Degrees
Synchrocheck 4 delta phase
Volts
Phasor measurement unit 1 phase A voltage magnitude
Degrees
Phasor measurement unit 1 phase A voltage angle
Volts
Phasor measurement unit 1 phase B voltage magnitude
Degrees
Phasor measurement unit 1 phase B voltage angle
Volts
Phasor measurement unit 1 phase C voltage magnitude
Degrees
Phasor measurement unit 1 phase C voltage angle
Volts
Phasor measurement unit 1 auxiliary voltage magnitude
Degrees
Phasor measurement unit 1 auxiliary voltage angle
Volts
Phasor measurement unit 1 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 1 positive-sequence voltage angle
Volts
Phasor measurement unit 1 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 1 negative-sequence voltage angle
Volts
Phasor measurement unit 1 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 1 zero-sequence voltage angle
Amps
Phasor measurement unit 1 phase A current magnitude
Degrees
Phasor measurement unit 1 phase A current angle
Amps
Phasor measurement unit 1 phase B current magnitude
Degrees
Phasor measurement unit 1 phase B current angle
Amps
Phasor measurement unit 1 phase C current magnitude
Degrees
Phasor measurement unit 1 phase C current angle
Amps
Phasor measurement unit 1 ground current magnitude
Degrees
Phasor measurement unit 1 ground current angle
Amps
Phasor measurement unit 1 positive-sequence current magnitude
Degrees
Phasor measurement unit 1 positive-sequence current angle
Amps
Phasor measurement unit 1 negative-sequence current magnitude
Degrees
Phasor measurement unit 1 negative-sequence current angle
Amps
Phasor measurement unit 1 zero-sequence current magnitude
Degrees
Phasor measurement unit 1 zero-sequence current angle
Hz
Phasor measurement unit 1 frequency
Hz/s
Phasor measurement unit 1 rate of change of frequency
---
Phasor measurement unit 1 configuration change counter
%
Source 1 phase A current total harmonic distortion
%
Source 1 phase A current second harmonic
%
Source 1 phase A current third harmonic
%
Source 1 phase A current fourth harmonic
%
Source 1 phase A current fifth harmonic
%
Source 1 phase A current sixth harmonic
%
Source 1 phase A current seventh harmonic
%
Source 1 phase A current eighth harmonic
%
Source 1 phase A current ninth harmonic
G60 Generator Protection System
APPENDIX A
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents