GE G60 Instruction Manual page 623

Ur series generator protection system
Hide thumbs Also See for G60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 21 of 68)
ADDR
REGISTER NAME
41A7
Clock Events Enable / Disable
41A8
Time Zone Offset from UTC
41A9
Daylight Savings Time (DST) Function
41AA
Daylight Savings Time (DST) Start Month
41AB
Daylight Savings Time (DST) Start Day
41AC
Daylight Savings Time (DST) Start Day Instance
41AD
Daylight Savings Time (DST) Start Hour
41AE
Daylight Savings Time (DST) Stop Month
41AF
Daylight Savings Time (DST) Stop Day
41B0
Daylight Savings Time (DST) Stop Day Instance
41B1
Daylight Savings Time (DST) Stop Hour
Oscillography (Read/Write Setting)
41C0
Oscillography Number of Records
41C1
Oscillography Trigger Mode
41C2
Oscillography Trigger Position
41C3
Oscillography Trigger Source
41C5
Oscillography AC Input Waveforms
41D0
Oscillography Analog Channel n (16 items)
4200
Oscillography Digital Channel n (63 items)
Trip and Alarm LEDs (Read/Write Setting)
42B0
Trip LED Input FlexLogic Operand
42B2
Alarm LED Input FlexLogic Operand
User Programmable LEDs (Read/Write Setting) (48 modules)
42C0
FlexLogic Operand to Activate LED
42C2
User LED type (latched or self-resetting)
42C3
...Repeated for User-Programmable LED 2
42C6
...Repeated for User-Programmable LED 3
42C9
...Repeated for User-Programmable LED 4
42CC
...Repeated for User-Programmable LED 5
42CF
...Repeated for User-Programmable LED 6
42D2
...Repeated for User-Programmable LED 7
42D5
...Repeated for User-Programmable LED 8
42D8
...Repeated for User-Programmable LED 9
42DB
...Repeated for User-Programmable LED 10
42DE
...Repeated for User-Programmable LED 11
42E1
...Repeated for User-Programmable LED 12
42E4
...Repeated for User-Programmable LED 13
42E7
...Repeated for User-Programmable LED 14
42EA
...Repeated for User-Programmable LED 15
42ED
...Repeated for User-Programmable LED 16
42F0
...Repeated for User-Programmable LED 17
42F3
...Repeated for User-Programmable LED 18
42F6
...Repeated for User-Programmable LED 19
42F9
...Repeated for User-Programmable LED 20
42FC
...Repeated for User-Programmable LED 21
42FF
...Repeated for User-Programmable LED 22
4302
...Repeated for User-Programmable LED 23
4305
...Repeated for User-Programmable LED 24
4308
...Repeated for User-Programmable LED 25
430B
...Repeated for User-Programmable LED 26
430E
...Repeated for User-Programmable LED 27
4311
...Repeated for User-Programmable LED 28
4314
...Repeated for User-Programmable LED 29
GE Multilin
RANGE
0 to 1
–24 to 24
0 to 1
0 to 11
0 to 6
0 to 4
0 to 23
0 to 11
0 to 6
0 to 4
0 to 23
3 to 64
0 to 1
0 to 100
0 to 4294967295
0 to 4
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
G60 Generator Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
hours
0.5
F002
---
1
F102
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F237
---
1
F238
---
1
F239
---
1
F001
---
1
F001
---
1
F118
%
1
F001
---
1
F300
---
1
F183
2 (16 samples/
---
1
F600
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F127
1 (Self-Reset)
DEFAULT
0 (Disabled)
0
0 (Disabled)
0 (January)
0 (Sunday)
B
0 (First)
2
0 (January)
0 (Sunday)
0 (First)
2
5
0 (Auto.
Overwrite)
50
0
cycle)
0
0
0
0
0
B-29

Advertisement

Table of Contents
loading

Table of Contents