Printing Signal Array
Data (cont.)
Printing Data
The data printed via the
of which lists the following three values:
•
- this is the printout line number, which locates the data
Index
point within the complete body of data.
•
Upstream
- this is the amplitude of the signal from the upstream
transducer at the listed index number.
•
Downstream
- this is the amplitude of the signal from the
downstream transducer at the listed index number.
Note: The printouts generated from the
submenus will appear after the
listings.
The data printed in this array permits a comparison of the relative
signal strengths of the upstream and downstream transducers, which
are used to calculate a single flow measurement.
SIGNL
submenu consists of 1024 lines, each
CROSS
printout, as separate
SIGNL
March 2003
and
BOTH
4-11