Pipe Wall

Path Length

Axial Length

Entering K-Factors

Programming Site Data
4. Use the numeric keys to enter the known thickness of the Pipe
Wall. Press
.
[ENT]
IMPORTANT: Because the units cannot be independently chosen for
this parameter, the value must be entered in the same
units used for the pipe OD.
If the pipe wall thickness is not available, look up the value in a table
of standard pipe size data or use the Model GF868's on-line Help
Menu (see the Programming Manual for details).
5. Press
= inch or
[F1]
[F2] = feet
Path Length (P) of the ultrasonic signal. Press
will only accept values from 1/8 to 900 in.)
Note: GE Panametrics has calculated both the transducer signal
path length
(P)
and the transducer signal axial length
based on the exact transducer configuration used for the
application. These values are engraved on the flowcell and/or
are included in the documentation supplied with the meter.
6. Press
[F1]
= inch or
[F2] = feet
Axial Length (L) of the ultrasonic signal and press
Note: GE Panametrics has calculated both the transducer signal
path length
(P)
and the transducer signal axial length
based on the exact transducer configuration used for the
application. These values are engraved on the flowcell and/or
are included in the documentation supplied with the meter.
7. Press
[F1] = OFF
to disable or
factors.
If you press OFF, skip to step 8.
If you press ON, complete the steps below.
= NO to retain the current K-factor table and
a. Press
[F1]
proceed directly to step 8, or press
factor Table.
Note: If velocity vs. K-factor data was not provided with the Model
GM868, the K-factor table can not be edited.
b. Enter the Number of K-factors to be entered into the table.
Press
. (The meter will only accept values from 2 to 20.)
[ENT]
March 2003
to select the units. Then, enter the
[ENT]
. (The meter
to select the units.Then, enter the
[ENT]
[F2]
= ON to enable Multiple K-
= YES to Edit The K-
[F2]
(L)
,
.
(L)
,
1-13