10 Technical data
Altitude
Cooling
Fans (only for
type 709061/X-0X-250...)
Resistance to climatic con-
ditions
Installation position
Test voltage
Creepage distances
Housing
Power loss
Maximum temperature of
the heat sink
Weight
Standard accessories
116
≤ 2000 m above MSL
Caution: At site altitudes > 1000 m above MSL, the ampacity of the power
controller decreases by 0.86 % per 100 m
- Natural convection up to a load current of 200 A
- From 250 A of load current, forced convection
- At installation heights over 1000 m, the ampacity of the power controller de-
creases
v Chapter 2.1.3 "Admissible load current depending on the ambient tem-
perature and the site altitude"
Depending on the load voltage of the power controller, the fan terminal X14
must be supplied with the voltage specified below.
The lead protection must be between 2 A and a maximum of 5 A.
The fan is temperature-controlled, switches on automatically when the device
temperature reaches 85 °C, and remains in operation until the device tem-
perature falls below 70 °C.
Load voltage of the power
controller
Load voltage AC 24 V
Load voltage AC 42 V
Load voltage AC 115 V
Load voltage AC 230 V
Load voltage AC 265 V
Load voltage AC 400 V
Load voltage AC 460 V
Load voltage AC 500 V
Rel. humidity ≤ 85 % annual average, no condensation 3K3 according to
EN 60721
Vertical
According to EN 50178 Tab. 18
8 mm between mains voltage circuit and SELV circuits
For type 709061/X -0X-020...
12.7 mm between mains voltage circuit and SELV circuits
From type 709061/X -0X-032...
SELV = Separate Extra Low Voltage (safe low voltage)
Plastic, flammability class UL94 V0, color: cobalt blue RAL 5013
The power loss can be calculated using the following empirical formula:
P
= 20 W + 1.3 V × I
v
Load
110 °C
Load current 20 A
Load current 32 A
Load current 50 A
Load current 100 A
Load current 150 A
Load current 200 A
Load current 250 A
1 operating manual
V1.04/EN/00561071 [Thyristor Power Switch TYA 201]
Tolerances
-20 to +15 %, 48 to 63 Hz
-20 to +15 %, 48 to 63 Hz
-15 to +10 %, 48 to 63 Hz
-15 to +10 %, 48 to 63 Hz
A
approx. 1.1 kg
approx. 2.1 kg
approx. 2.7 kg
approx. 3.8 kg
approx. 8.5 kg
approx. 9.5 kg
approx. 10.2 kg
Fan specifications
AC 24 V/30 VA
AC 115 V/30 VA
AC 230 V/30 VA