Sign In
Upload
Manuals
Brands
JUMO Manuals
Controller
709062/8-01-020
JUMO 709062/8-01-020 Manuals
Manuals and User Guides for JUMO 709062/8-01-020. We have
1
JUMO 709062/8-01-020 manual available for free PDF download: Operating Manual
JUMO 709062/8-01-020 Operating Manual (120 pages)
TYA 202 series Thyristor power controller in a three-phase economy circuit
Brand:
JUMO
| Category:
Controller
| Size: 5 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Editorial
9
Typographical Conventions
10
Warning Symbols
10
Note Symbols
11
Performing an Action
11
Display Types
11
Order Details
12
Scope of Delivery
13
Accessories
13
General Accessories
13
Brief Description
14
Standards, Approvals, and Conformity
15
2 Mounting
17
Important Installation Notes
17
Environmental Conditions
18
Filtering and Interference Suppression
19
Admissible Load Current Depending on the Ambient Temperature and the Site Altitude
19
Wall Mounting with Screws (Default)
21
Mounting on DIN Rail (Accessories)
24
Dimensions
25
Type 709062/X-0X-020-XXX-XXX-XX-25X
25
Type 709062/X-0X-032-XXX-XXX-XX-25X
26
Type 709062/X-0X-050-XXX-XXX-XX-25X
27
Type 709062/X-0X-100-XXX-XXX-XX-25X
28
Type 709062/X-0X-150-XXX-XXX-XX-25X Type 709062/X-0X-200-XXX-XXX-XX-25X
29
Type 709062/X-0X-250-XXX-XXX-XX-25X
30
Clearances (All Types)
30
3 Electrical Connection
31
Plug-In Screw Terminals with 20 a
31
Type 709062/X-0X-20-XXX-XXX-XX-25X
31
Cable Lugs and Plug-In Screw Terminals as of 32 a
32
Type 709063/X-0X-032-XXX-XXX-XX-25X Type 709063/X-0X-050-XXX-XXX-XX-25X
33
Type 709062/X-0X-100-XXX-XXX-XX-25X
35
Type 709062/X-0X-150-XXX-XXX-XX-25X Type 709062/X-0X-200-XXX-XXX-XX-25X
36
Type 709062/X-0X-250-XXX-XXX-XX-25X
37
Connection Diagram
38
Switch-On Sequence
41
Three-Phase Economic Circuit Master-Slave for Resistive Loads in Star-, Delta Connection or Transformer Loads (Resistive-Induktive)
41
4 Operation
43
Display after Switching on the Device
43
Display and Control Elements
44
Appearance of Measured Values
44
Meaning of the Displayed Measured Values
45
Appearance in the Configuration Level
47
Appearance of Error Messages and Special Statuses
47
Operating Level
48
Device Data
48
Power Controller
49
Setpoint Value Configuration
49
Monitoring
51
5 Configuration
53
Configuration Level
53
Device Data
54
Language Wizard Active
54
Temperature Unit
54
Display Contrast
54
Switch-Off
54
Display Lighting
54
Apply Default Settings
54
Power Controller
54
Thyristor Control
54
Subordinate Control Loop
55
Cycle Time
56
Min. on Period
56
Α Start
56
Α Start Angle
56
Soft Start
56
Soft Start Type
57
Soft Start Duration
57
Current Limiting
57
Current Limit Value
58
Resistance Limitation
58
Resistance Limit Value
58
Dual Energy Management
58
Analog Inputs
59
Current Measuring Range
59
Current Measuring Range, Start
59
Current Measuring Range, End
59
Voltage Measuring Range
59
Voltage Measuring Range, Start
59
Voltage Measuring Range, End
59
Setpoint Value Configuration
60
Setpoint Specification
60
Input in the Event of an Error
60
Value in the Event of an Error
60
Maximum Actuating Variable
60
Base Load
61
Monitoring
62
Limit Value Monitoring
62
Min. Limit Value Alarm
62
Max. Limit Value Alarm
63
Limit Value Hysteresis
63
Load Monitoring
63
Limit Value Load Monitoring
63
Load Type Load Monitoring
63
Teach-In Type Load Monitoring
63
Mains Voltage Drop Monitoring
64
Control Loop Monitoring
64
Digital Inputs
65
External Toggling of Setpoint Specification
65
Setpoint Specification When Toggling
65
Value When Toggling
65
Ext. Current Limiting
65
External Current Limit Value
65
Key Lock
66
External Switch-Off of Display Lighting
66
Inhibit Input Control Direction
66
Control Direction, Digital Input1
66
Control Direction, Digital Input2
66
Digital Output
67
Output Mode
67
Control Direction, Digital Output
68
Analog Output
69
Signal Type, Actual Value Output
69
Value to be Output
69
Signal Range Start Value
69
Signal Range End Value
69
Rs422/485
69
Baud Rate
69
Data Format
69
Device Address
69
Min. Response Time
69
Profibus-Dp
70
Device Address
70
Data Format
70
Ethercat
70
Fieldbus
70
Device ID
70
(Alias-Adr.)
70
Changing Codes
70
Code, Manual Mode
70
Code, Operating Level
70
Configuration Example
71
6 Special Device Functions
73
Detection of Load Faults
73
Teach-In
75
Manual Mode
76
Setpoint Specification in Manual Mode
76
Configuring Teach-In (Prerequisite for Teach-In in Manual Mode)
76
Performing Teach-In in Manual Mode
77
Setpoint Specification Via Potentiometer
78
Dual Energy Management
78
Subordinate Control Loop
81
Closed Control Loop Without Subordinate Control
81
Closed Control Loop with Subordinate Control
82
Resistance Limitation (R-Control)
87
Current Limiting
88
Α Start
88
Monitoring of the Mains Voltage Drop
89
Firing Pulse Inhibit
89
Thyristor Control Logic (Switch)
90
7 Setup Program
91
Hardware
91
Compatible Operating Systems
91
Installation
92
Program Start
94
Forgotten the Code
95
Changing the Language of the Device Texts
96
8 Error Messages and Alarms
97
Binary Signal for Collective Fault
101
Replacing a Defective Semiconductor Fuse
102
Accessories: Semiconductor Fuses
103
Semi-Conductor Fuses Type 709062/X-0X-20
103
Semi-Conductor Fuses Type 709062/X-0X-32
104
9 What to Do, if
107
10 Technical Data
109
Voltage Supply, Fan Specifications for 250A, Load Current
109
Galvanic Isolation
109
Analog Inputs (Master Only)
110
Analog Output (Actual Value Output Master Only)
110
Display and Measuring Accuracy
110
Digital Inputs
110
Digital Output (Fault Signal Output Master Only)
110
General Specifications
111
Approvals / Approval Marks
113
11 Certificates
115
China
117
Advertisement
Advertisement
Related Products
JUMO 709062/8-01-50
JUMO 709062/8-01-150
JUMO 709062/8-01-100
JUMO 709062/8-01-250
JUMO 709062/8-01-32
JUMO 709062/8-01-200
JUMO 703042
JUMO 703045
JUMO 703048
JUMO 709061/8-01-250
JUMO Categories
Transmitter
Measuring Instruments
Controller
Thermostat
Voice Recorder
More JUMO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL