2-10. GAS BURNER
ASSEMBLY
(GAS MODELS)
(Continued)
2-11. THERMOCOUPLE
(GAS MODELS)
2-18
19. Remove control panel and install it in slot above the door.
20. Connect gas control valve wires to the thermostat and high
temperature limit control as labeled.
21. Install control panel per paragraph 2-4.
22. Uncap and reconnect the main gas supply line to the fryer.
Turn on the main gas supply
LEAKING GAS MAY CAUSE AN EXPLOSION.
CHECK FOR LEAKS PER OPERATOR'S MANUAL
PARAGRAPH 2-8.
23. Connect the service cord to the wall receptacle, or close
circuit breakers.
24. Relight gas pilot per the instructions in paragraph 2-10 of
the Operator's Manual.
The thermocouple controls the gas control valve. It generates
voltage in the millivolt. This voltage signals the gas control valve
to remain open to the pilot and burner. When the voltage is not
generated the gas control valve will shut off, not allowing gas to
the pilot and main burner.
If converting from natural gas to propane gas or from propane
gas to natural gas, conversion must be done by a qualified
technician.
TO AVOID INJURY OR PROPERTY DAMAGE, BE-
FORE STARTING THIS PROCEDURE, MOVE THE
MAIN POWER SWITCH TO THE OFF POSITION.
DISCONNECT THE MAIN CIRCUIT BREAKER AT
THE CIRCUIT BREAKER BOX OR UNPLUG THE
SERVICE CORD AT THE WALL RECEPTACLE.
TURN OFF THE MAIN GAS SUPPLY TO THE FRY-
ER. DISCONNECT AND CAP THE SUPPLY LINE TO
FRYER, OR EXPLOSION COULD RESULT.
Model 500/600
305

Hide quick links: