2-14. PRESSURE
REGULATION/
EXHAUST (Continued)
Condensation Box Fitting
Condensation Box Bottom
3-34
Pressure Gauge Cleaning Steps
1. Remove gauge and check inside the pipe fittings from dead
weight body. Make certain fittings are clean and open.
2. Clean and reinstall the gauge.
Condensation Box Assembly
The deadweight valve and solenoid exhausts are directed into a
condensation box, located in the rear of the fryer. Should
this box become clogged, water would spew from the top of the
box. The box can be cleaned by running a wire or long brush
from the top of the box, through hole in the bottom of the box,
or the bottom of the box can be removed to clean.
Condensation Box Bottom Removal
Model 500-SN: KB021JB to HB013JB
Model 600-SN: KA021JJ to GA085JB
When cleaning the frypot, pour a cup of cleaning solution
into the large exhaust hose at the top of the exhaust tank
(see figure at left). This helps prevent the box from getting
clogged.
1. Loosen fitting at the bottom of the box.
2. Using a Phillips head screwdriver, remove 4 screws securing
the bottom of the box and pull bottom from assembly.
Step 1
3. Clean outlet hole in box bottom and check condensation
tube for clogs, and clean if necessary.
4. Reinstall box bottom and condensation line.
5. Seal box bottom with silicone sealant and unit is now ready
Step 2
for operation.
Model 500/600
305