2-15. FILTERING SYSTEM
(Continued)
2-48
Installation
1. Attach the filter rinse hose with its quick disconnect female
fitting to the other half male fitting inside the door, next to
the filter valve handle.
2. To do this slide back the spring ring on the female end of
the quick disconnect fitting and let it snap into place over
the other half male fitting.
3. With a quick tug on the hose, insure the quick disconnect
is locked into position.
Step 1
Filter Valve Description
The filter valve is a 3/8 inch two-way stainless steel ball valve. If
this valve should develop leaks the entire valve must be replaced.
To avoid electrical shock or property damage, move the
power switch to "OFF" and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Removal
1. Drain the shortening from the frypot.
2. Remove the filter drain pan from the fryer.
3. Remove the cotter pin, handle, and extension rod.
4. Remove the pipe from between the filter pump and valve.
If fryer is equipped with optional filter rinse hose attach-
ment, disconnect pipe from filter valve.
5. Use an adjustable wrench and remove the valve.
6. Replace the valve and reassemble in reverse order.
Model 500/600
305