Gas Burner Assembly (Gas Models) - Henny Penny 500 Technical Manual

Electric/gas cfa pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-10. GAS BURNER
ASSEMBLY
(GAS MODELS)
MAIN GAS
CONTROL VALVE
THERMOCOUPLE
PILOT
HOLDER
305
Description
The gas model fryer has a gas burner assembly consisting of a
burner casting, orifices, thermocouple, pilot holder, and main
gas control valve.
ORIFICE
BURNER
CASTING
Safety Precautions
If converting from natural gas to propane gas or from propane
gas to natural gas, conversion must be done by a qualified
service technician.
TO AVOID PERSONAL INJURY OR PROPERTY
DAMAGE, BEFORE STARTING THIS PROCEDURE,
MOVE THE MAIN POWER SWITCH TO THE OFF
POSITION. DISCONNECT THE MAIN CIRCUIT
BREAKERS AT THE CIRCUIT BREAKER BOX OR
UNPLUG SERVICE
CORD FROM WALL RECEPTACLE. TURN OFF THE
MAIN GAS SUPPLY TO THE FRYER AND DISCON-
NECT AND CAP THE MAIN SUPPLY LINE TO FRY-
ER, OR POSSIBLE EXPLOSION COULD RESULT.
1. Remove the control panel per paragraph 2-4.
2. Label and remove the gas control valve wires.
3. Place the control panel back in upright position, in the
metal flanges.
Model 500/600
2-15