1-5. DIAGNOSTIC MODE
DETAILS (Continued)
1-28
The number of Beeped Done Too Long Cycles for this batch
of peanut oil is reported next. Note that this value does not yet
include the Cook Cycles from today.
"D8: BEFORE TODAY "
"D8: 7% OF LOADS"
"D8: BEEPED 'DONE'"
"D8: TOO LONG"
"D8: ON THIS OIL"
(Press the DOWN button...)
Finally, the controller identifies percentage of Beeped Done Too
Long Cycles for the previous batch of peanut oil:
"D8: LAST OIL"
"D8: 6% OF LOADS"
"D8: BEEPED 'DONE"
"D8: TOO LONG"
D 9: Irregular Loading Report
For most Cook Cycles, the controller determines when the product
was placed into the peanut oil. This report identifies the percentage
of cycles for which this determination was not successful.
This drop detection detects most loads, but can fail for several
reasons. Anytime the detection routine fails to find the true drop
point, the controller logs an irregular loading count.
Examples of failed drop detection might be: the Operator takes too
long to load the product to the time he presses the start button, or
the Operator cooks a very light product load, one or two filets, for
example.
In these instances, no drop point will be found and that Cook Cycle
counts as an Irregular Loading Cycle. Only products that have
more than 5% of loads with missed detection's are reported.
Model 500/600