Henny Penny 500 Technical Manual page 195

Electric/gas cfa pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

PFE-500 Oil Migration Inspection
A
Figure 1.
A
B
D
A
Figure 2.
1219 US 35 West P.O. Box 60 Eaton, OH 45320 (937)456-8400 Fax (937)456-8402 www.hennypenny.com
B
Electro-Mechanical
Contactor
Mercury Contactor
B C
D
A
A
Electro-Mechanical
Contactor
B
Temperature probe /
thermostat fitting
C
High limit fitting
D
Heating Element Fittings
Inspection 16
Disconnect power to the fryer
1.
Lower the control board.
2.
Inspect the area behind the
3.
control board for oil that has
seeped through any of the
fittings (Figure 2).
Inspect if oil is seeping through
4.
the temperature probe /
thermostat fitting, the high limit
fitting or any of the six heating
element fittings (Figure 2). If oil is
found seeping through fittings
but is not touching either
contactor, this situation does not
shut down the fryer, but would
need to be cleaned as soon as
possible.
If oil is excessive enough that it is
5.
touching either contactor (figure
1 & 2), shut down the fryer until
the oil migration issue is taken
care of. In this situation, the
contactors need to be replaced,
the oil needs to be cleaned up
and the fittings need to be
cleaned and resealed
Rev. B