PFE-500 and PFG-600 Latch, Catch and Latch Spring Inspection
A
Figure 1.
B
Figure 2.
Contour of catch
should match
Figure 3.
Rev. C
December 2016
Objective
To make sure the latch, catch and latch spring
are properly installed and are within tolerances
for safe operation.
C
A
Catch
B
Latch
C
Latch Spring
Catch Inspection
1. Slide gauge #162410 along the entire
width of the pot catch (figure 2).
2. If this gauge does not slide over the
catch, or the lip of the catch does not
match the profile of the gauge as shown
in figure 3 and 4, the catch is out of
tolerance. The pressure fryer would
need to be taken out of service until the
fry pot has been replaced.
Inspection 22