1-5. DIAGNOSTIC MODE
DETAILS (Continued)
1-22
If the fryer has witnessed two or more low voltage warnings today,
the following report is displayed:
"D4: CAN'T TEST"
"D4: HEAT CAPACITY"
"D4: DUE TO"
"D4: VOLTAGE"
"D4: PROBLEMS"
Otherwise, if the assessed heat capacity rating is presently "good"
and there has been at most one heat-up today that failed to achieve
the expected rate, the following report is displayed:
"D4: HEATING"
"D4: CAPACITY"
"D4: IS FINE"
Otherwise, if the heat capacity is presently assessed as "bad",
or presently assessed as "good" but two or more heat-ups today
have not reached the expected heat-up rate, the following report
sequence is generated:
"D4: YOU HAD 75%"
"D4: SLOW HEATS"
"D4: TODAY"
(Press
)
"D4: HAVE 20%"
"D4: SLOW HEATS"
"D4: THIS OIL"
(Press
)
"D4: HAD 0%"
"D4: SLOW HEATS"
"D4: LAST OIL"
(Press
)
If the heat capacity is assessed as bad (low heat-up rate on last
heat-up, and on three of the last four heat-ups), then the heating
coils are suspect and the following message is displayed:
"D4: CHECK COILS,"
"D4: CONTACTORS,"
"D4: AND WIRING"
Model 500/600