1-6. INFORMATION MODE
DETAILS
305
6. PREV DAY - SUN
Press
to step through following data. During each step, press
to choose the day of the week, of the past 7 days.
FUNCTION
Day this data was recorded for
Time of day last heat-up was completed
Peak heat-up rate (°F/Sec) for last heat-up
Was that day's last heat-up acceptable?
Heat cap. status (based on last 4 ht-ups)
Number of monitored heat-ups that day
Number of slow heat-ups
Max time to heat 270°F to 310°F that day
Lowest peak rate for that day's heat-ups
Maximum voltage that day (when fryer on)
Minimum voltage that day (when fryer on)
No. of
"LOW VOLTAGE"
Maximum Amp Draw that day
Minimum Amp Draw that day
No. of
"LOW AMPS"
warnings that day
Non-cooking time (hh:mm) while fryer was on
Oil wear accumulated that day
Total number of Cook Cycles that day
Number of cycles started before ready
No. cycles quit early (0:11 or more remaining)
No. cycles beeped *DONE* 21 sec or more
Individual product cook counts
Individual product not detected counts
Individual product slow cook counts
Individual product frozen or overloaded
During steps 6V through 6Y, press the product buttons (or
Manual Prog) to see data on individual product items.
Press
to continue onto 7-day totals log.
DISPLAY EX:
6A. DATE
6B. LAST HEAT 8:15P
6C. LAST RATE 0.88
6D. LAST OK? YES
6E. HEAT CAP GOOD
6F. HEAT-UPS
6G. SLOW HT'S 0
6H. MAX HT TM 1:11
6I. MIN RATE 0.67
6J. MAX VOLT 102%
6K. MIN VOLT 98%
warnings
6L. LO VOLT'S 0
6M. MAX AMPS
6N. MIN AMPS
6O. LO AMP'S 0
6P. IDLE HRS 7:09
6Q. OIL WEAR
6R. TOT CK'S 18
6S. NOT RDY'S 2
6T. QUIT 11+
6U. DONE 21+
6V. Px CK CT
6W. Px NO DET
6X. Px SLO CT
6Y. Px FRZ/OV
Model 500/600
APR-8
7
35
34
39
1
3
12
1
0
1
1-35