Henny Penny 500 Technical Manual page 97

Electric/gas cfa pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-15. FILTERING SYSTEM
(Continued)
305
Pump Removal
(Continued)
4. To replace the pump and motor assembly, insure the
main power has been removed from the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
5. Remove the cover from the junction box and remove the
wire nuts attaching wires leading into the flexible conduit
going to the motor.
6. Loosen the two screws securing the flexible conduit to
the 90º conduit connector (8). (Refer to Figure 3-25.)
7. Remove tubing to the pump. (Refer to Figures 3-21
and 3-24.)
8. Remove hardware attaching the motor to the motor base
bracket and remove motor and pump assembly.
Filter Pump Motor
Protector - Manual Reset
The filter pump motor is equipped with a manual reset button in
the event the motor's thermal protector actuates. This reset button
is located on the rear of the motor. Wait approximately 5 minutes
before attempting to reset this protector device.
To prevent burns caused by splashing shortening, the
unit's main power switch must be in the OFF position
before resetting the filter pump motor's manual reset
protection device.
Model 500/600
2-51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600

Table of Contents