Henny Penny 500 Technical Manual page 53

Electric/gas cfa pressure fryer
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-7. HIGH TEMPERATURE
LIMIT CONTROL
(ELECTRIC AND
GAS MODELS)
(Continued)
High Limit Capillary Tube
409
3. Remove the two electrical wires from the high
temperature limit control.
4. Check for continuity between the two terminals after
resetting the control. If the circuit is open, replace the
control, then continue with this procedure. (If the circuit
is closed, high limit is not defective. Reconnect the two
electrical wires.)
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
Step 3
breaker, or unplug cord at wall receptacle.
1. If the capillary tube is broken or cracked, control will open,
Electric
shutting off electrical power. The control cannot be
reset.
2. Drain shortening from the frypot.
3. Remove control panel.
4. Loosen small inside screw nut on capillary tube.
5. Remove capillary bulb from bulb holders inside the frypot.
6. Straighten the capillary tube.
7. Remove larger outside nut that threads into pot wall.
8. Remove the two screws that secure the high limit to
the high limit bracket.
Gas
9. Remove defective control from control panel area.
10. Insert new 450 degree high limit (part no. 16738) and replace
screws.
11. Uncoil capillary line, starting at capillary tube, and
insert through frypot wall.
Step 1
To avoid electrical shock or other injury, the capillary
line must run under and away from all electrical power
wires. The tube must never be in contact with the
electrical power wires or terminals.
Model 500/600
2-7