10.2

How to Set Table Information

20SSC-H has 2 procedures to set table information, via FX Configurator-FP or by a sequence program.
Setting table information by sequence program
To set table information by sequence program, write each setting to 20SSC-H buffer memory by TO
instruction, or move instructions (MOV, etc.) for direct specification.
For details on buffer memory assignments, refer to the following.
Note
It is strongly recommended to set and store table information in the flash memory via FX Configurator-FP.
When table information is set by sequence program, a considerable amount of the sequence program and
devices are used, which makes the program complicated and increases the scan time.
Setting table information on FX Configurator-FP
Set value with the X-axis, Y-axis, XY-axis table information edit windows in FX Configurator-FP.
For details on operation of FX Configurator-FP, refer to the following manual.
• Operation method
1) Double-click "File name"
information" in the file data list.
2) The selected X-axis table information, Y-axis table information or XY-axis table information edit window is
displayed.
Note
Note that the procedures to set the table information from FX Configurator-FP and a sequence program are
different.
→ "Edit" → "X-axis table information", "Y-axis table information" or "XY-axis table
10 Table Operation
10.2 How to Set Table Information
→ Refer to Sections 10.3 and 11.5
→ FX Configurator-FP Operation Manual