Device Assignments - Mitsubishi FX3U-20SSC-H User Manual

Melsec-f programmable controllers
Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
12.2

Device Assignments

Input
Error reset
STOP
Forward rotation limit
Reverse rotation limit
Forward rotation JOG
Reverse rotation JOG
Mechanical zero return command
START command
Selection of 1-speed positioning operation
Selection of table operation (individual)
Selection of table operation (simultaneous)
Control data
Operation pattern
selection
Operation command 1
Target address 1
Operation speed 1
Table operation start No.
Name
1-speed Positioning operation
Interrupt 1-speed constant quantity feed
2-speed Positioning operation
Interrupt 2-speed constant quantity feed
Interrupt stop
Variable speed operation
Manual pulse generator
Linear interpolation operation
Linear interpolation (interrupt stop)
operation
Table operation (individual)
Table operation (simultaneous)
Not available
Error reset
STOP
Forward rotation limit
Reverse rotation limit
Forward rotation JOG
Reverse rotation JOG
Mechanical zero return command
Not available
Relative/absolute address specification
START command
Simultaneous start flag
m code OFF command
Change command in operation disabled
Speed change command in positioning
control
Target position change command
in positioning control
Not available
Device No.
X-axis
Y-axis
X000
X010
X001
X011
X002
X012
Use external wiring with NC
contacts.
X003
X013
X004
X014
X005
X015
X006
X016
X007
X017
X020
X021
X022
X023
X024
-
M0
M100
M1
M101
M2
M102
M3
M103
M4
M104
M5
M105
M6
M106
M7
M107
M8
M108
M9
M109
M10
M110
M11 to M15
M111 to M115 Always OFF
M20
M120
M21
M121
M22
M122
M23
M123
M24
M124
M25
M125
M26
M126
M27
M127
Always OFF
M28
M128
M29
M129
M30
M130
M31
M131
M32
M132
M33
M133
M34
M134
M35
M135
Always OFF
D501, D500
D601, D600
D503, D502
D603, D602
D521
D621
12 Program Example
12.2 Device Assignments
Remark
141
11
12
13
A

Advertisement

Table of Contents
loading

Table of Contents