1.

Introduction

1.1

Outline

FX
-20SSC-H type positioning block (hereinafter referred to as 20SSC-H) is a special function block
3U
applicable to SSCNET III.
20SSC-H can perform positioning control by servo motor via SSCNET III applied servo amplifier.
1. 2-axis control is possible
One 20SSC-H controls 2 axes.
20SSC-H applies the 1-speed positioning and interrupt 1-speed constant quantity feed operations for
constant quantity feed control, and also the linear interpolation and circular interpolation operations.
2. Connection to servo amplifier by SSCNET III is possible
20SSC-H connects directly to the MELSERVO (our company's servo amplifier: MR-J3-B) via SSCNETIII.
• Connection using the SSCNET III cable between the 20SSC-H and the servo amplifier and between servo
amplifiers reduces wiring. (Maximum length is 50m.)
• Using the SSCNET III cable (optical communication) makes connections less susceptible to
electromagnetic noise, etc. from the servo amplifier.
• Setting the servo parameters on the 20SSC-H side and writing/reading the servo parameters to/from the
servo amplifier using SSCNET III is possible.
• Actual current values and error descriptions the servo amplifier can be checked by the buffer memories of
the 20SSC-H.
3. Easy application of absolute position detection system
• The servo amplifier with absolute position detection enables the absolute positioning detection system.
• Once the zero position is established, the zero return operation at power startup is not necessary.
• The absolute position system allows the establishment of zero position by the data set type zero return.
In this case, wiring for near-point DOG, etc. is not required.
4. Easy maintenance
Various data such as positioning data, parameters, etc. can be saved to the flash memory (ROM) in the
20SSC-H.
This allows the data to be saved without battery.
5. Connectable PLC
• The connected FX
• For connection to the FX
14
or FX
PLC reads/writes the positioning data from/to the 20SSC-H.
3U
3UC
PLC, the FX
3UC
2NC
→ For positioning control, refer to Chapter 9.
-CNV-IF or FX
-1PS-5V is needed.
3UC
1 Introduction