Control Data

The control data is user-specified data for controlling the positioning system.
For X-axis: BFM #500 to #599
For Y-axis: BFM #600 to #699
Caution
Do not use unlisted BFMs for changing values not described in this section.

11.4.1 Target address 1 [BFM #501, #500, BFM #601, #600]

This data item sets a target position or travel for positioning operation distance as the target address 1.
BFM Number
X-axis
Y-axis
BFM
BFM
#501,#500
#601,#600
*1.
Refer to the section shown below for details on the user unit.
Note
• The positioning operation differs as follows depending on the procedure to specify the absolute address or
relative address.
- With absolute address: travels from the current position to the target position.
The rotation direction depends whether target address 1 is larger or smaller than the current address.
- With relative address: moves by the specified travel distance from the current position. The rotation
direction depends on the target address sign (+/-).
• The units of the value are user-specified and include the position data magnification.

11.4.2 Operation speed 1 [BFM #503, #502, BFM #603, #602]

This data item sets the operation speed 1 for positioning operations.
BFM Number
X-axis
Y-axis
BFM
BFM
#503,#502
#603,#602
*1.
Refer to the section shown below for details on the user unit.
Note
• Set the operation speed 1 slower than the maximum speed.
If the operation speed 1 exceeds the maximum speed, 20SSC-H operates at the maximum speed.
• You can change the operation speed during positioning operation if changing speed is enabled (when not
setting the flag for "speed change disable during operation").
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
Set the value within -2,147,483,648 to 2,147,483,647 PLS in the converted pulse data
Setting range: -2,147,483,648 to 2,147,483,647 [User unit]
Set the value within 1 to 50,000,000Hz in converted pulse data.
→ For details on the operation speed change function, refer to Subsection 7.5.2
11 Buffer Memory (Parameters & Monitored Data)
Description
*1
Description
*1
11.4 Control Data
Default
K0
→ Refer to Section 7.7
Default
K1
→ Refer to Section 7.7