Mitsubishi FX3U-20SSC-H User Manual page 151

Melsec-f programmable controllers
Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
X-axis
• When turnig X007 "X-axis START command" to ON with X022 "X-axis selection of table operation
(individual)" turned ON, multi-speed operation preset to X-axis table information starts. After 10,000,000
pulses of travel in the current value incrementing direction, operation decelerates to stop.
• When turning X007 "X-axis START command" to ON after the table operation ends, the positioning
operates by the same travel distance again.
• When turnig X001 "X-axis stop" to ON during positioning, the positioning decelerates to stop.
• m codes are output in the with mode. At the start of each operation, the m code ON flag becomes "1" and
the m code number is stored.
When the m code number of 10003, the m code OFF command turns ON, and the m code turns OFF.
Y-axis
• When turnig X017 "X-axis START command" to ON with X023 "X-axis selection of table operation
(individual)" turned ON, multi-speed operation preset to X-axis table information starts. After 10,000,000
pulses of travel in the current value incrementing direction, operation decelerates to stop.
• When turning X017 "X-axis START command" to ON after the table operation ends, the positioning
operates by the same travel distance again.
• When turnig X011 "X-axis stop" to ON during positioning, the positioning decelerates to stop.
• m codes are output in the with mode. At the start of each operation, the m code ON flag becomes "1" and
the m code number is stored.
When the m code number of 11003, the m code OFF command turns ON, and the m code turns OFF.
2. Setting table information
Set the X-axis/Y-axis table information as follows in FX Configurator-FP.
1) X-axis table information
2) Y-axis table information
12 Program Example
12.3 Explanation of Operation
145
11
12
13
A