Related parameters, control data and monitor data

Item
Positioning parameter
Zero return direction BFM #14000 b10
Operation
DOG input logic
parameter 1
Zero-point signal
count start timing
Maximum speed
Acceleration time
Deceleration time
Mechanical zero-point address
Zero return mode
Zero return speed (high speed)
Zero return speed (creep)
Zero-point signal count
Zero return torque limit
FLS/RLS signal
selection
DOG signal
selection
External signal
FLS/RLS signal
selection
logic
Dog signal logic
BFM number
X-axis
Y-axis
BFM #14200 b10
BFM #14000 b12
BFM #14200 b12
BFM #14000 b13
BFM #14200 b13
BFM #14009,#14008
BFM #14209,#14208
BFM #14018
BFM #14218
BFM #14020
BFM #14220
BFM #14029,#14028
BFM #14229,#14228
BFM #14031
BFM #14231
BFM #14025,#14024
BFM #14225,#14224
BFM #14027,#14026
BFM #14227,#14226
BFM #14030
BFM #14230
BFM #14040
BFM #14240
BFM #14044 b0
BFM #14244 b0
BFM #14044 b1
BFM #14244 b1
BFM #14044 b8
BFM #14244 b8
BFM #14044 b9
BFM #14244 b9
8.1 Mechanical Zero Return Control
Description
OFF: The current value decreasing direction
ON: The current value increasing direction
OFF: The NO contact for the DOG input logic of
20SSC-H.
ON: The NC contact for the DOG input logic of
20SSC-H.
OFF: The rear edge of DOG
ON: The front edge of DOG
Setting range: 1 to 2,147,483,647(user unit)
Setting range: 1 to 5000ms
Setting range: 1 to 5000ms
Setting range:-2,147,483,648 to
2,147,483,647(user unit)
Set the value within -2,147,483,648 to
2,147,483,647PLS in the converted pulse data
0: DOG type
1: Data-set type
2: Stopper type (1)
3: Stopper type (2)
Setting range: 1 to 2,147,483,647(user unit)
Set the value within 1 to 50,000,000Hz in converted
pulse data to satisfy the following conditions.
Zero return speed (high speed)
The 20SSC-H operates at the maximum speed
when the zero return speed (high speed) >
maximum speed
Setting range: 1 to 2,147,483,647(user unit)
et the value within 1 to 50,000,000Hz in converted pulse
data to satisfy the following conditions.
Zero return speed (creep)
zero return speed (high
speed)
maximum speed
The 20SSC-H operates at the maximum speed
when the zero return speed (high speed) >
maximum speed
Setting range: 0 to 32767PLS
×
Setting range: 1 to 10000(
0.1%)
OFF: The RLS/RLS signal of the servo amplifier is not
used.
ON : The FLS/RLS signal of the servo amplifier is used.
OFF: The DOG signal of the servo amplifier is not used.
ON: The DOG signal of the servo amplifier is used.
OFF: The NO contact for the FLS/RLS signal logic of
the servo amplifier.
ON: The NC contact for the FLS/RLS signal logic of
the servo amplifier.
OFF: The NO contact for the DOG input logic of the
servo amplifier.
ON: The NC contact for the DOG input logic of the
servo amplifier.
8 Manual Control
1
2
3
*1
*1
4
*1
5
maximum speed
*1
6
7
8
9
10
67