ADASH Ltd.
Trim Screens
After RUN3 measurement you can continue with the job when you are not satisfied with the results. These next
steps do not required trial mass measurements already. After each measurement the next masses are
recommended. The trim screens are very similar to screens in single plane balancing.
Balancing Errors
Balancing errors and warnings can occur during the job.
The effect of trial weight is low
This message informs you that the effect of the trial mass is low.
The percentual value is derived from ratio (amplitude of change vector/ amplitude of RUN1 vector).
The percentage value is derived from the ratio (amplitude of vector change/ amplitude of RUN 1 vector).
A warning is displayed when the change is less than 20% but bigger than 1%. You can continue with balancing
after this warning and use these values.
An error is displayed when the change is less than 1%. You cannot continue with balancing after this error,
because such a small change is not acceptable. You could get incorrect results.
For further technical and contact information visit www.adash.eu, email: info@adash.cz
78
Adash 4400 – VA4Pro