Adash A4900 Vibrio M Pocket Manual
Hide thumbs Also See for A4900 Vibrio M:

Advertisement

Quick Links

A4900 Vibrio M
pocket guide

Advertisement

Table of Contents
loading

Summary of Contents for Adash A4900 Vibrio M

  • Page 1 A4900 Vibrio M pocket guide...
  • Page 2: Table Of Contents

    A4900 Vibrio M pocket guide Basic information Switch on/off Basic control Basic menu Measurement screens Saving data from measurement screen Light Memory - Route measurement 12-13 Setup Volume Proximity measurements 16-17...
  • Page 3: Basic Information

    Basic Information Switch ON/OFF Top panel Micro USB for data transfer IR non-contact temperature sensor Phones output LED stroboscope ACC ICP® - sensor input Buttons Arrow buttons Press the Enter button to switch on the device Enter button Firmware version Batteries Serial number Filters Sensor sensitivity...
  • Page 4: Basic Control

    Basic control Basic menu Arrow buttons To open the Menu press the Enter button (on any > measurement screen) switch between the measurement modes > select the right or left item from the menu at the bottom > move between items (up/down) in menu Enter button >...
  • Page 5: Measurement Screens

    Measurement screens Use the arrow buttons to move between the measurement screens Overall values - RMS Frequency bands RMS vibration values: RMS vibration values: 10 - 1000 Hz in mm/s (ips) 0.5 - 1.5 kHz in g 1.5 - 5 kHz in g 0.5 - 16 kHz in g 5 - 16 kHz in g Automatic speed detection...
  • Page 6: Saving Data From Measurement Screen

    Saving data from measurement screen Light (*available for the Vibrio M only, FASIT screen cannot be saved) Press the Enter button on any measurement screen Torch Used memory The instrument can be used as a torch in this mode Press the Enter button [SAVE] Press any button to switch off the Torch mode Strobo...
  • Page 7: Memory - Route Measurement

    Memory - Route measurement (*available for the Vibrio M only) 1. Data transfer 5. Point selection Use the Arrow buttons to switch Firstly the route must be between the points in route loaded to the device from the DDS software Press the Enter button [SEL] to confirm the selection 2.
  • Page 8: Setup

    Connect phones to the output (3.5mm jack) Speed Auto Manual Alarms Adash Default (speed is required) R13 (rigid, group 1 and 3) F13 (flexible, group 1 and 3) Select the Volume option from ISO 10 816 R24 (rigid, group 2 and 4)
  • Page 9: Proximity Measurements

    Proximity measurements Proximity option (*available for the Vibrio MP only) (*available for the Vibrio MP only) Speed Use the arrow keys to move between The A4900 Vibrio MP needs to be the measurement screens connected to a proximity sensor for proximity measurement! (The default sensor sensitivity is set to 7.87 mV/μm, 200 mV/mil)
  • Page 10 Notes: Notes:...
  • Page 11 Master the language of your machinery. Adash, spol. s r.o. Hlubinská 1379/32 702 00 Ostrava Czech Republic tel.: +420 596 232 670 e-mail: info@adash.com www.adash.com © Adash 2016...