Adash 4400 VA4 Pro User Manual page 47

Vibration analyzer
Table of Contents

Advertisement

ADASH Ltd.
user
Cursor for time signals -
single
periodic
delta
Cursor for spectra -
single
harmonic
sideband
delta
Cursor position
Delta X
the time or frequency interval used for delta cursor computation, manual entry available
Axe X -
lin, log
Axe Y -
lin, log
Axe Z -
time
speed
regular
Order Z -
first in front, last in front
Detect Type - RMS, 0-P, P-P Y axe type
Peaks List -
on, off
Synch Table
on, off
SubSynch - value under speed frequency
Synch - value on speed frequency and harmonics
NonSynch - total value decreased of SubSynch and Synch
Elect - value on line frequency and harmonics (setting in Global Settings / Power/Line Frequency)
All values are in displayed spectrum unit and in % of total value.
Bearing Faults - if the bearing type (or parameters) is defined and the tacho was used for speed measurement,
then the fault frequencies is displayed.
For further technical and contact information visit www.adash.eu, email: info@adash.cz
user defines Y range for all graphs independently of data values
standard simple cursor
multiplied cursor with several additions of delta time
band cursor with delta time length
standard cursor
cursor with several additions of delta
cursor with one addition delta
cursor with one addition delta
the time or frequency position of cursor in the selected graph, manual entry available
scale according time of measurements
scale according the speed of machine (tacho must be used)
regular scale
the 5 highest spectrum lines table
table of values synchronized with speed and line frequency
the order of measurements on Y axe