Single Plane Balancing; Run 1 Screen - Adash 4400 VA4 Pro User Manual

Vibration analyzer
Table of Contents

Advertisement

ADASH Ltd.
Adash 4400 – VA4Pro

Single plane balancing

RUN 1 screen

The red bearing house is the recommended point for sensor mounting. But you can use any other place, which
is suitable for measurements.
Press START button and measurement will be taken.
If you press the Edit button, then you can manually enter all values (balancing calculator function). Use the Tab
for shift between values.
Use the down arrow to move to the next screen.