Automatic Change Of View; Buttons In Machine View; Fit; Arrow Mode - Adash 4400 VA4 Pro User Manual

Vibration analyzer
Table of Contents

Advertisement

ADASH Ltd.

Automatic change of view

When the measurement is ran, the machine view replaced by measurement view.

Buttons in Machine View

Fit

Auto-zoom of machine in window.

Arrow Mode

Changes the arrows functions.

Point

Moves the point selection (blinking circle). When the new selection is confirmed by OK, then the selected
direction is also moved to that point.

Direction

Moves the direction selection (on selected point). The new direction for measurement can be manually entered
by Enter Direction button.

Zoom/Move/Rotation

Zoom/Move/Rotation of machine.

Blink on/Blink off

The directions which are not measured yet can be blinking.

Hide on/Hide off

The directions which are measured yet can be hide.

Start/Stop Animation

Run or stop animation.

Enter Direction

Manual entry for direction number.

Start

Starts new measurement.

Buttons in Measurement View

The most of buttons have the same function as in Analyzer mode.
180° on/180°off
Sometimes it is possible to mount the sensor to direction which is defined in geometry. Usually in such case is
possible to mount the sensor in opposite direction. The use this button and change the phase of 180 degrees.
For further technical and contact information visit www.adash.eu, email: info@adash.cz