Orders measurement

This name means order analysis.

1x amp+phase measurement

The smaller resolution means longer time signal for evaluation. We do not recommend to use always the
minimum value ( speed/64), because you will wait for results longer (much longer). Use the small resolution only
in cases, when your signal contains two close frequencies and you need to separate them. For 50Hz speed the
speed/4 means the band (43.75Hz, 56.25Hz) and the speed/64 means (49.61Hz, 50.39Hz).

Phase Shift

The measurement of phase shift (between two channel A and B), amplitude ratio and coherence on speed
frequency (with tacho) or manually entered frequency.
See the New Advanced chapter for more information about Resolution item.