Measurement Parameters Setting - Adash A3900 II User Manual

Online monitoring system
Table of Contents

Advertisement

ADASH Ltd.

Measurement parameters setting:

Enter, Space - Open menu (measuring will continue)
Esc
- Close menu (if measuring isn't stopped)
m - Stop measuring / Start measuring (System is automatically resetting after Start measuring).
Most of the parameters setting needs to restart measuring.
s
- Save new setting
'1' - Measured unit (mm/s, in/s, g)
Measured unit can be changed only if the measuring is stopped (by pressing the key 'm').
Submenu of measured unit is opened by pressing the key '1'.
'1'
g-rms
'2'
g-peak
'3'
mm/s-rms
'4'
ips-rms
'5'
mm/s-peak
'6'
ips-peak
Measured unit can be chosen from this submenu by pressing the key '1', '2', '3', '4', '5' or '6'.
A new measured unit is confirmed by pressing the key 's'. New measuring is started by pressing the
key 'm'.
If measuring of acceleration is choosen (g/rms or g/peak), then HF(5-16kHz)/LIN(0-16kHz) setting is
added to menu.
Attention!!! – if measured unit is changed by user, then Alarm value, Alert value, Loop max. value
and Loop min. value are reset to zero!
h - setting of frequency band of acceleration [g] – LIN [g] (0.5Hz–16kHz), or HF [g] (5kHz–16kHz).
It can be changed only if the measuring is stopped by pressing the key 'm'.
This menu is displayed only for measuring of acceleration. A setting of frequency band of acceleration
can be changed by pressing the key 'h'. A new setting of frequency band of acceleration is confirmed
by pressing the key 's'. New measuring is started by pressing the key 'm'.
'2' - Sensor sensitivity
Sensor sensitivity can be changed only if the measuring is stopped (by pressing the key 'm').
Sensor sensitivity can be changed by pressing the key '2'. A new sensor sensitivity is confirmed by
pressing the key 's'. New measuring is started by pressing the key 'm'.
Attention!!! sensor sensitivity has not to be zero
'3' - Alarm value (relay on)
Alarm value can be changed only if the measuring is stopped (by pressing the key 'm').
A Alarm value can be changed by pressing the key '3'. If Alarm value is zero, relay is deactivated. A
new Alarm value is confirmed by pressing the key 's'. New measuring is started by pressing the key
'm'.
measured data
----------------------------------------------------------------------------------------------------------------------------------------
lower than Alarm
value
more than Alarm
value
ADASH Ltd., Czech republic, tel.: +420 596 232 670, fax: +420 596 232 671, email: info@adash.cz
measuring of acceleration
measuring of acceleration
measuring of velocity
measuring of velocity
measuring of velocity
measuring of velocity
ALARM indicator
is ON
is OFF
For more information visit www.adash.com
contacts COM-1
switched on
switched off