Measurement; Status Bar; Measurement Screens; Overall (Rms) And Peak (0-P) Values - Adash 4300 VA3Pro User Manual

Table of Contents

Advertisement

ADASH Ltd.

Measurement

Press Start to initiate the measurement. The speed detection runs first (see chapter Speed Detection).

Status bar

There is a Status bar at the top part of the display. It provides information about the settings and status of the
measurement. If the measurement is running there is a red icon labeled meas flashing in the top right corner.
Ch1:
The number of the channel being used
1140 RPM Auto:
the value and unit of speed and the method of speed detection
Auto: the speed is detected from the frequency spectrum
Manual: the speed is entered manually by the user
Tacho: the speed is detected by the tacho
Alarms:
The standards used for stating the limit values

Measurement screens

You can switch between the measurement screens with the left and right arrow buttons.

Overall (RMS) and Peak (0-P) values

Measurement of Overall and Peak value in the following frequency bands:
velocity: 10 Hz - 1000 Hz
acceleration: 0.5 kHz – 25.6 kHz
The colour describing the condition of the machine (green, yellow, red) is determined according to the speed
value and vibration value (RMS, Peak).
Spectrum up to 200Hz – mechanical looseness detection
FFT analysis of vibrations in the range 2 Hz - 200 Hz in mm/s RMS
The 3 maximum peaks found are displayed
The peaks are arranged according to the vibration amplitude.
For further technical and contact information visit www.adash.com, email: info@adash.cz
28
Adash 4300 – VA3Pro

Advertisement

Table of Contents
loading

Table of Contents