Leaks From One Level To Another - Dell Z9000 Configuration Manual

10/25/40/50/100gbe throughput
Hide thumbs Also See for Z9000:
Table of Contents

Advertisement

Beginning Metric Style
narrow transition
narrow transition
narrow transition
wide transition
wide transition
wide transition
wide transition
Moving to transition and then to another metric style produces different results.
Table 20. Metric Value when the Metric Style Changes Multiple Times
Beginning Metric
Next Metric Style
Style
wide
transition
wide transition
transition
wide
transition
wide transition
transition

Leaks from One Level to Another

In the following scenarios, each IS-IS level is configured with a different metric style.
Table 21. Metric Value with Different Levels Configured with Different Metric Styles
Level-1 Metric Style
narrow
narrow
Intermediate System to Intermediate System
Final Metric Style
narrow
wide transition
transition
wide
narrow
narrow transition
transition
Resulting Metric
Value
truncated value
truncated value
truncated value
truncated value
Level-2 Metric Style
wide
wide transition
Resulting IS-IS Metric Value
original value
original value
original value
original value
default value (10) if the original
value is greater than 63. A
message is sent to the console.
default value (10) if the original
value is greater than 63. A
message is sent to the console.
truncated value (the truncated
value appears in the LSP only).
The original isis metric value
is displayed in the show config
and show running-config
commands and is used if you
change back to transition metric
style.
Next Metric Style
Final Metric Value
wide
original value is
recovered
wide transition
original value is
recovered
narrow
default value (10). A
message is sent to
the logging buffer
narrow transition
default value (10). A
message is sent to
the logging buffer
Resulting Metric Value
original value
original value
423

Advertisement

Table of Contents
loading

Table of Contents