A.5 Electrical Card Specifications - Cisco ONS 15454 Reference Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Appendix A
Hardware Specifications

A.5 Electrical Card Specifications

This section provides specifications for the EC1-12, DS1-14, DS1N-14, DS1/E1-56, DS3/EC1-48,
DS3-12, DS3N-12, DS3i-N-12, DS3-12E, DS3N-12E, DS3XM-6, DS3XM-12, and filler cards.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance
Information document.
A.5.1 EC1-12 Card Specifications
The EC1-12 card has the following specifications:
OL-9217-01
Optocoupler isolated
Label customer provisionable
Severity customer provisionable
Common 32 V output for all alarm inputs
Each input limited to 2 mA
Termination: 50-pin AMP champ connector
Alarm outputs
Number of outputs: 16
Switched by opto MOS
Triggered by definable alarm condition
Maximum allowed open circuit voltage: 60 VDC
Maximum allowed closed circuit current: 100 mA
Termination: 50-pin AMP champ connector
Environmental
Overvoltage protection: as in ITU-T G.703 Annex B
Operating temperature: –40 to +65 degrees Celsius
Operating humidity: 5 to 95 percent, noncondensing
Power consumption: 3.00 W max., from +5 VDC from AIC-I, 10.2 BTU/hr max.
Dimensions of AEP board
Height: 0.79 in. (20 mm)
Width: 13.0 in. (330 mm)
Depth: 3.5 in. (89 mm)
Weight: 0.4 lb (0.18 kg)
Input
Bit rate: 51.84 Mbps +/– 20 ppm
Frame format: SONET
Line code: B3ZS
A.5 A.5 Electrical Card Specifications
Cisco ONS 15454 Reference Manual, R7.0.1
A-15

Advertisement

Table of Contents
loading

Table of Contents