Appendix C Network Element Default - Cisco ONS 15454 Reference Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

C.2 C.2 Card Default Settings
settings except those relating to protection (1+1 bidirectional switching, 1+1 reversion time, 1+1
revertive switching, bidirectional line switched ring [BLSR] ring reversion time, BLSR ring revertive
switching, BLSR span reversion time, and BLSR span revertive switching), which apply to subsequent
provisioning.
Note
C.2 Card Default Settings
The tables in this section list the default settings for each SONET card. Cisco provides several types of
user-configurable defaults for Cisco ONS 15454 optical, electrical, storage access networking, and
Ethernet (or data) cards. Types of card defaults can be broadly grouped by function, as outlined in the
following subsections. For information about individual card settings, refer to the "Change Card
Settings" chapter of the Cisco ONS 15454 Procedure Guide.
When the card level defaults are changed, the new provisioning done after the defaults have changed is
Note
affected. Existing provisioning remains unaffected.
To view DWDM card defaults consult the Cisco ONS 15454 DWDM Reference Manual.
Note
The following types of defaults are defined for SONET cards.
C.2.1 Configuration Defaults
Most card and port-level configuration defaults correspond to settings found in the CTC card-level
Provisioning tabs.
The full set of Automatic Laser Shutdown (ALS) configuration defaults can be found in the CTC
Note
card-level Maintenance > ALS tab for supported cards. ALS defaults are supported for OC3-8,
OC-48ELR, OC-192, OC192-XFP, and MRC-12 cards.
Configuration defaults that correspond to settings that are reachable from the CTC card-level
Provisioning tabs (except as noted) include the following types of options (arranged by CTC subtab):
Note
Cisco ONS 15454 Reference Manual, R7.0.1
C-2
Changing some node-level provisioning via NE defaults can cause CTC disconnection or a
reboot of the node in order for the provisioning to take effect. Before you change a default, check
in the Side Effects column of the Defaults editor (right-click a column header and select Show
Column > Side Effects) and be prepared for the occurrence of any side effects listed for that
default.
Line—(DS-N, EC1-12, OC-N, MRC-12, G-series, and CE-series cards) Line-level configuration
settings.
MRC-12 line configuration defaults are defined on a per OC-N rate basis.
SONET STS—(OC-N and EC1-12 cards) SONET STS-level configuration settings.
Appendix C
Network Element Defaults
OL-9217-01